What is the URA 60:40 rule for B1 industrial space in Singapore?

The URA 60:40 rule requires that a minimum of 60% of total gross floor area in Business 1 (B1) industrial developments must be dedicated to core industrial activities such as manufacturing, assembly, and core technology R&D. A maximum of 40% may be allocated to ancillary purposes, including executive offices and showrooms.

§ URA Non-Residential Development Control Guidelines § Planning Act 1998
View Specifications →
industrial

What is the difference between Business 1 (B1) and Business 2 (B2) industrial zoning in Singapore?

Business 1 (B1) zoning accommodates light, clean industrial operations with nuisance buffers under 50 meters, including software development and assembly. Business 2 (B2) zoning permits general and heavy industrial uses—such as metal fabrication, chemical warehousing, and heavy engineering—requiring environmental nuisance buffers exceeding 50 meters under NEA guidelines.

§ URA Master Plan Written Statement § NEA Code of Practice on Pollution Control § Planning Act 1998
View Specifications →
industrial

What are JTC subletting policy caps and anchor tenant guidelines for industrial properties?

JTC Corporation requires anchor lessees on standard industrial land allocations to occupy at least 70% of total Gross Floor Area for approved primary industrial activities. Subletting is capped at a maximum of 30% GFA, requires prior JTC written consent, incurs sublet fees, and restricts sub-tenants to qualifying industrial operations.

§ JTC Industrial Land Policy § Jurong Town Corporation Act 1968 § Building and Construction Authority (BCA) Guidelines
View Specifications →
office

Central chilled water vs VRV aircon: what are the operating cost differences for office tenants?

Central chilled water operates during fixed building hours—typically 8:00 AM to 6:00 PM on weekdays—with after-hours cooling incurring overtime charges from $80 to $130 hourly per zone. Variable Refrigerant Volume (VRV/VRF) systems provide autonomous, 24/7 cooling billed directly via individual kilowatt-hour meters, significantly lowering after-hours operational expenses.

§ BCA Green Mark Certification Scheme § SS 530: Code of Practice for Energy Efficiency Standard § SS 553: Code of Practice for Air-Conditioning and Mechanical Ventilation
View Specifications →
office

What is floor plate efficiency and core-to-window depth in Singapore Grade A Core CBD offices?

Singapore Grade A Core CBD office buildings typically achieve floor plate efficiencies between 82% and 90% Net Lettable Area relative to Gross Floor Area. Optimal core-to-window depth spans 12 to 15 meters, providing column-free floorplates that maximize perimeter daylight penetration and enable high-density workstation layouts of 80 to 100 square feet per employee.

§ URA Development Control Parameters for Commercial Developments § BCA Code on Accessibility in the Built Environment § Singapore Standard SS 531: Code of Practice for Lighting of Work Places
View Specifications →
retail

What are the key technical and planning criteria for URA Change of Use to Restaurant (F&B)?

Converting commercial premises to restaurant use mandates URA Planning Permission. Critical technical requirements include dedicated kitchen exhaust discharging above roof level (4,000 to 8,000 m³/hr), approved grease traps complying with PUB trade effluent standards, and three-phase electrical power provisioning between 100A and 150A.

§ Planning Act 1998 (Planning Permission for Change of Use) § Sewerage and Drainage Act (PUB Trade Effluent Discharge Regulations) § NEA Code of Practice on Environmental Health (COPEH)
View Specifications →
shophouse

What are the SCDF fire safety and staircase compliance requirements for commercial shophouses?

Commercial shophouse upper-floor occupancies under the SCDF Fire Code require compliant means of escape, including dual staircases when one-way travel distances exceed thresholds, fire-rated enclosures for timber floors/staircases, and automatic fire alarm detection systems, emergency exit lighting, and independent fire-rated compartments separating ground-floor commercial spaces.

§ SCDF Code of Practice for Fire Precautions in Buildings (Fire Code) § Fire Safety Act 1993 § URA Conservation Guidelines for Historic Districts
View Specifications →